Water and surfaces as potential sources of pathogenic bacteria in Harare hospitals’ intensive care units

creativework.publisherPlovdiv University Press “Paisii Hilendarski”
dc.contributor.authorDururu, Mathias
dc.contributor.authorMuchesa, Petros
dc.contributor.authorChidzwondo, Farisai
dc.contributor.authorMangoyi, Rumbidzai
dc.date.accessioned2024-07-10T10:39:38Z
dc.date.available2024-07-10T10:39:38Z
dc.date.issued2024-07-10
dc.description.abstractWater and contaminated hospital surfaces have been reported as major causes of Hospital acquirеd (nosocomial) infections (HAIs), a significant global safety problem for both patients and medical staff. However, the frequency of Intensive Care Units (ICU)-HAIs has been reported to be at least 2-3 times greater in low- to middle-income countries, particularly in Zimbabwe, than in high-income countries. Thus, this study aimed at determining the presence of pathogenic bacteria in water and surfaces from selected high-risk areas within the intensive care units of three hospitals (A, B, and C) in Harare, Zimbabwe. Water and surface samples were collected and processed within 24 hours of collection. The water samples were tested for the presence of microbial indicators using standard methodology of microbial plating. The surface swabs were also investigated using microbial plating. The organisms that were found to be present in surface samples were then identified using biochemical tests and 16S polymerase chain reaction (16S PCR). The results showed no bacteria present in any of the water samples tested during the study. However, using morphological characteristics, six different types of bacteria were identified in surface samples. The bacteria identified to be present on surfaces were Escherichia coli, Salmonella, Shigella, Staphylococcus, Pseudomonas, and Streptococcus. Hospital A surfaces may be the major cause of some bacterial infection outbreaks, hence, there is a need for better ways of reducing contamination of surfaces in the intensive care units.
dc.identifier.issn1314-6246
dc.identifier.urihttps://doi.uni-plovdiv.bg/handle/store/202
dc.language.isoen
dc.subjectIntensive care units
dc.subjectwater
dc.subjectsurfaces
dc.subjectbacteria
dc.subjectbiochemical tests
dc.subject16S polymerase chain reaction
dc.titleWater and surfaces as potential sources of pathogenic bacteria in Harare hospitals’ intensive care units
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
jbb20241035.pdf
Size:
699.23 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
73 B
Format:
Item-specific license agreed to upon submission
Description: